{"product_id":"canchecked-tcc01-thermocouple-amplifier-type-k-sensor-controller","title":"CANchecked TCC01 thermocouple amplifier \/ Type-K sensor controller","description":"\u003cdiv id=\"tab-wp\" class=\"mb-lg\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"tab-content\" id=\"article-tabs\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"col-12 col-md-8\" id=\"tab-description\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"panel-body\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"tab-content-wrapper\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"desc\" data-mce-fragment=\"1\"\u003e\n\u003ch1 data-mce-fragment=\"1\"\u003eCANchecked TCC01 Thermocouple Amplifier\u003c\/h1\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eOne of the smallest and fastest type-K converters in the world\u003c\/h2\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eOptimal for type-K sensors in connection with digital displays and standalone ECU's\u003c\/h3\u003e\n\u003cp align=\"justify\" data-mce-fragment=\"1\"\u003eThe TCC01 is a so-called \"Thermocouple Amplifier\" - i.e. a device that amplifies and converts the signal of a type K sensor - our simple Thermocouple Converter. With our TCC01 you can easily connect your exhaust gas temperature sensor:\u003cbr data-mce-fragment=\"1\"\u003ePlug the type K probe into the converter on one side and use the DTM connector on the other side for the power supply by means of 5V, ground and the signal for your control unit or data display.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eFeatures TCC01\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReliable thermocouple amplifier\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCold junction compensated type K input\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDTM06-3S connector\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eStandard mini thermocouple plug\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRetaining strap for attachment with M6 screw or cable tie\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLinear temperature curve from 0-1000°\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb data-mce-fragment=\"1\"\u003eDelivery content\u003c\/b\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTCC01 in housing\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDTM connector with locking\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e3 pins to crimp yourself\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e3 pre-crimped connection cables\u003c\/li\u003e\n\u003c\/ul\u003e\nSupport for a variety of devices. Any device that has an analog input for 0-5V signals can be used as a receiver - e.g.:\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAEM\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEcumaster\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEmtron\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDTAfast\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHaltech\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLinkECU\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eKMS van Kronenburg\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMaxxECU\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMBE\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMegasquirt\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMotec\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSyvecs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVEMS\u003c\/li\u003e\n\u003c\/ul\u003e\nBut the type K converter can not only be used for exhaust gas temperatures. Also for liquids (1mm thermocouples) and gases (0.5mm thermocouples).\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTechnical specifications\u003c\/b\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOnly 180uA power consumption\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVery fine resolution with 4mV per °C\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCalibration: 0V = 0°C (32°F) and 5V = 1000° (1832°F)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAccuracy: maximum 2% deviation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInternal cold junction compensation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFor measuring gases, liquids and other media\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSupport of different type K elements (also 0.5, 1, 3 and 5mm diameter)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb data-mce-fragment=\"1\"\u003eInstallation\u003c\/b\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe installation of the Thermocouple Converter TCC01 (Thermocouple Amplifier) ??is easy. It should be placed in a dry and not too hot place, for example behind the bulkhead. You can use the integrated tab for attachment. Due to the special construction, it is possible to attach additional TCC01 parallel next to each other. For maximum fixation, you can attach the included tab to the TCC01 module with superglue.\u003cbr data-mce-fragment=\"1\"\u003eCANchecked displays are preconfigured to connect the TCC01. To do this, connect signal to AIN2.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSeveral TCC01 modules\u003c\/b\u003e\u003cbr data-mce-fragment=\"1\"\u003eHowever, you often need two or more modules, for example with TwinScroll charging manifolds. Here you can simply plug the modules into each other.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-12 col-md-4\" id=\"tabs-other\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"tab-attributes\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"panel-heading dpflex-a-center dpflex-j-between\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"panel-title h3 m0\" data-mce-fragment=\"1\"\u003eFeatures\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel-body\" data-mce-fragment=\"1\"\u003e\n\u003cul class=\"product-attributes blanklist p-att\" data-mce-fragment=\"1\"\u003e\n\u003cli class=\"dpflex\" data-mce-fragment=\"1\"\u003e\n\u003cstrong class=\"first mr-xxs\" data-mce-fragment=\"1\"\u003eModel: \u003c\/strong\u003e\u003cspan class=\"right dpflex-a-c dpflex-wrap\" data-mce-fragment=\"1\"\u003edigital\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"dpflex-a-c\" data-mce-fragment=\"1\"\u003e\n\u003cstrong class=\"first mr-xxs\" data-mce-fragment=\"1\"\u003eItem weight: \u003c\/strong\u003e\u003cspan class=\"tag\" data-mce-fragment=\"1\"\u003e0,70 kg\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"recommendations hidden-print\" data-mce-fragment=\"1\"\u003e\n\u003csection class=\"panel-slider panel-default x-sell mb-lg\" id=\"slider-xsell\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"panel-heading\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"panel-title dpflex-a-center dpflex-j-between mb-spacer mb-xs\" data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"VADpro","offers":[{"title":"Default Title","offer_id":67837705093288,"sku":"syw1794152298485","price":68.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0753\/9084\/5096\/files\/canchecked-tcc01-thermocouple-amplifier-type-k-sensor-controller_1.jpg?v=1794152303","url":"https:\/\/silkdrapefit.shop\/products\/canchecked-tcc01-thermocouple-amplifier-type-k-sensor-controller","provider":"My Store","version":"1.0","type":"link"}